• long8 - 龙8 - 龙八(国际)游戏官方网站

    TransformerHigh voltage cabinetLow voltage cabinetOutdoor complete equipment

    Oil-immersed Power Transformer

    PRODUCT PARAMETERS:
    Executive standards: IEC, GB, ANSI/IEEE, NEMA
    Capacity: 6300kVA~180000 kVA
    Rated voltage on the primary side: 110kV~121kVA
    Secondary side rated voltage: 6.3kV~38.5kVA
    Number of tap off gears: 5-17
    Frequency: 50/60Hz
    Number of phases: three-phase
    Connection group: Yd11/YNd11, etc
    Impedance: 10%~14%

    Hotline:+86-570-4982909 销售热线:+86-570-4982880
    Description
    Feature
    Parameter
    The iron core of 110kV oil-immersed power transformer is made of high quality oriented silicon steel sheets by multi-stage step lamination, and the surface is coated with curing paint. Low loss, low noise, etc. The coil adopts the internal and external bracing structure, and the high-strength hard paper tube structure is used between the coil and the iron core, so as to effectively ensure the short circuit impact resistance. The fuel tank adopts the one-time forming and bending corrugated structure to increase the mechanical strength and make the appearance beautiful and generous. All-round positioning structure is adopted between the transformer body and the oil tank to ensure transportation and operation stability.
    Low loss: Meet the energy efficiency requirements in the standard GB20052-2020 "Energy Efficiency Limits and Levels for Power Transformers";
    Low noise: The self cooling noise level will reach below 60dB;
    Low partial discharge: The partial discharge volume should be controlled below 100pc;
    Strong short-circuit resistance: The coil is internally supported by a high-quality insulation skeleton, and the side wall of the fuel tank is formed by laser cutting in one go;
    Beautiful appearance: Full polishing and rust removal, powder electric spraying paint can achieve the spraying effect of household appliances;
    No leakage: All sealing flanges adopt groove structure, the oil drain valve adopts copper valve, and the radiator adopts vacuum butterfly valve to ensure sealing performance.

     

    Rated capacity

    KVA

    Level 1

    Level 2

    Level 3

     

    short circuit
    impedance

    %

    Empty loss

    W

    Load loss

    W

    Empty loss

    W

    Load loss

    W

    Empty loss

    W

    Load loss

    W

    6300

    4.1

    32

    4.8

    38

    5.9

    33

     10.5

    8000

    4.9

    38

    5.8

    38

    7.1

    40

    10000

    5.8

    45

    6.8

    45

    8.4

    48

    12500

    6.8

    53

    8.1

    53

    9.9

    56

    16000

    8.3

    65.7

    9.8

    65.7

    12.0

    69

    20000

    9.7

    79

    11.4

    79

    14.1

    84

    25000

    11.4

    94

    13.5

    94

    16.6

    99

    31500

    13.5

    111

    16.0

    111

    19.7

    117

    40000

    16.2

    133

    19.1

    133

    23.5

    141

    50000

    19.4

    158

    22.9

    158

    28.2

    166

    63000

    22.9

    187

    27.0

    187

    33.3

    198

    75000

    26.0

    212

    30.7

    212

    37.8

    224

    12~14

    90000

    29.9

    245

    35.4

    245

    43.5

    258

    120000

    37.3

    303

    44.4

    303

    54.2

    320

    150000

    44.1

    359

    52.1

    359

    64.1

    379

    180000

    49.5

    411

    58.5

    411

    72.0

    434


    Note: The data in the table is for reference only. The company reserves the right to make changes to the data and accepts special orders.

    Copyright © 2024 KERUN INTELLIGENT CONTROL CO.LTD. All rights reserved.

    友情链接: